Konica Minolta Network Cables CM SA User Manual

Skin Analysis Software CM-SA  
Installation Guide  
Software License Agreement  
The terms of the license agreement of the CM-SA software are provided in the Software License Agreement dia-  
log box displayed on-screen during the installation process. This software can be installed only if you agree to all  
the terms of the agreement.  
Safety Precautions  
Before you use the CM-SA software, we recommend that you thoroughly read this manual as well as the  
instruction manuals of your PC and the instrument.  
Notes on Installation  
• The CM-SA application software is designed to be used with the Windows XP, Windows Vista or Windows 7  
operating system. Note that neither operating system is included with this software.  
• One of these operating systems must be installed on the PC before this software can be installed.  
• When inserting the CD-ROM into the CD-ROM drive, note the correct orientation of the disc. Insert it gently.  
• Keep the CD-ROM clean and free from scratches. If the recorded surface becomes dirty or the label surface is  
scratched, a read error may result.  
• Avoid exposing the CD-ROM to rapid temperature changes and condensation.  
• Avoid leaving it in locations where it may be exposed to high temperatures from direct sunlight or heaters.  
• Do not drop the CD-ROM or subject it to strong impact.  
• Keep the CD-ROM away from water, alcohol, paint thinners, and other such substances.  
• Remove the CD-ROM from the CD-ROM drive while the computer is turned on.  
Notes on Storage  
• After using the CD-ROM, return it to its case and store in a safe place.  
• Avoid leaving the CD-ROM in locations where it may be exposed to high temperatures from direct sunlight or  
heaters.  
• The CD-ROM should not be kept in areas of high humidity.  
Every effort has been made to ensure the accuracy of the content of this software. However, should you have any  
questions or comments, please contact the nearest KONICA MINOLTA authorized service facility.  
Package Contents  
• Skin Analysis Software CM-SA Installation CD-ROM: 1  
• Installation Guide (this manual)  
• Authorized Service Facility  
The “Instruction Manual” is also installed in PDF form with a shortcut in the start menu during the software  
installation.  
To read the manual, go to <Start Menu -> All programs -> KONICAMINOLTA -> Skin Analysis Software CM-  
SA -> Manual> PDF file. You will need the Adobe Reader® from Adobe Corporation. The latest Adobe Reader®  
could be downloaded for free from the Adobe website. Also, it is possible to use the Adobe Reader® installer  
included with the installation CD-ROM for installation.  
(Example) When the CD-Rom is in E drive  
E:\Adobe Reader\EN  
Formal designations of application software used in this manual  
(Designation in this manual)  
Windows, Windows XP  
Windows, Windows Vista  
Windows, Windows 7  
(Formal designation)  
Microsoft® Windows® XP Professional Operating System  
Microsoft® Windows® Vista Business Operating System  
Microsoft® Windows® 7 Professional Operating System  
Trademarks  
• “Microsoft”, “Windows”, “Windows XP”, “Windows Vista” and “Windows 7” are registered trademarks of  
Microsoft Corporation in the U.S.A. and other countries.  
Other company names and product names mentioned in this manual are the registered trademarks or  
trademarks of their respective companies.  
9222-1895-53  
BCEBGA  
 
2.1 Connecting to a PC/Installing the USB Driver (When the RS-232C cable  
or USB cable is used.)  
Although the USB cable can be connected/disconnected while the instrument and PC are  
turned ON, you need to turn them OFF in the procedure below.  
1. Turn off both the instrument and the computer.  
2. Connect the instrument and the computer via the RS-232C cable or USB cable as illustrated. Connect the  
computer end of the cable to the serial port (when the RS-232C cable is used) or USB port (when the USB  
cable is used) of the computer.  
Instrument  
PC  
RS-232C cable or USB cable  
Notes:  
• Attach the connectors securely in the correct orientation. When the RS-232C cable is used, securing the  
connectors with screws prevents accidental disconnection.  
• Do not touch the terminals of the connector. Keep them clean and do not apply excessive force.  
• Use a cable of sufficient length. If the cable is too short, a connection failure or disconnection may  
result.  
• To disconnect the cable, grip the plug or connector securely. Do not pull the cable or bend it with  
excessive force.  
3. Turn on the instrument and the computer.  
4. Set the instrument to remote communication mode.  
For the setting procedure, refer to the instruction manual for the instrument.  
When the CM-700d/600d is connected, the remote communication mode is automatically set.  
Continue from step 5 only when you use the USB cable for the connection between your PC  
and the instrument.  
5. Install the instrument's USB driver for on the PC.  
Windows XP  
Windows Vista  
Windows 7  
5-1. The “Found New Hardware  
Wizard” starts up. Select [No,  
not this time] and click  
5-1. When the “Found New  
Hardware Wizard” starts up,  
select “Locate and install  
driver software.”  
5-2. A dialog box for confirming  
the User Account Control is  
displayed. Select  
5-1. A message saying  
“Installing device driver  
software” is displayed in the  
taskbar at the bottom right  
of the screen. Wait until the  
driver is installed. (The  
driver installation process  
may take several minutes.)  
5-2. A dialog box for confirming  
the User Account Control is  
displayed. Select  
“Next”.  
5-2. Select “Install the software  
automatically” as the  
method to search for the  
driver and click “Next”.  
5-3. A dialog box for confirming  
the Logo Test is displayed.  
Select “Yes”. The process to  
install the USB driver starts.  
5-4. When the installation is  
complete, click “Finish”.  
“Continue”.  
5-3. When the Windows security  
dialog box is displayed,  
select [Install this driver  
software anyway]. The  
process to install the USB  
driver starts.  
“Continue”.  
5-3. The installation finishes  
automatically and a  
notification is displayed in  
the taskbar.  
5-4. When the installation is  
complete, the dialog box  
will close automatically.  
3
 
6. If you were not able to install the USB driver using the procedure above, install it from Device Manager.  
From the Start menu, right-click “My Computer” or “Computer” and select “Properties” to open Device  
Manager. Right click “Spectrophotometer CM-700/600 Series” and select “Update Driver”. Select the  
folder where CM-SA has been installed and specify Kmsecm700.inf.  
7. Check which COM port of the PC the instrument has been assigned to.  
From the Start menu, right-click “My Computer” or “Computer” and select “Properties” to open Device  
Manager. Click “Ports (COM & LPT)” to expand it, and the assigned COM port number is displayed.  
Note: This COM port number is required when you start CM-SA and connect it with the instrument.  
®
2.2 Connecting to a PC/Establishing Bluetooth Connection (When the  
®
Bluetooth communication is used.)  
1. Turn on the instrument and the PC.  
2. Attach the Bluetooth® adapter to the USB port of the PC.  
For the installation and operation of the Bluetooth® adapter driver, refer to the instruction manual of the  
Bluetooth® adapter.  
3. Set the Bluetooth® communication function of the instrument to ON.  
For the procedure to set the Bluetooth® communication function, refer to the instruction manual of the  
instrument.  
When the Bluetooth® connection is recognized, the instrument will be displayed on the screen of the  
Bluetooth® adapter driver software. The instrument is identified with the device name  
“KMSEA_xxxxxxxx” (xxxxxxxx is the serial number of the instrument) and the device type “PDA”.  
4. Use the Bluetooth® adapter's driver software to check the COM port of the PC to which the instrument has  
been assigned.  
Note: This COM port number is required when you start CM-SA and connect it with the instrument.  
3. Major functions of the software  
(For details, refer to the Instruction Manual.)  
Skin data display  
Melanin Index  
Hb Index [Hemoglobin (oxidized and reduced) index]  
Hb SO2 Index (%) [Hemoglobin oxygen saturation index (%)]  
Colorimetric value display  
Graph display  
L*, a*, b*, Munsell value (Hue, Value, Chroma)  
Hue-Value Graph  
Hb Index-Melanin Index Graph  
Data output  
Saving/reading data in CM-SA original format  
Saving data in text (CSV) format  
[Melanin Index, Hb Index, Hb SO2 Index (%), L*, a*, b*, Munsell  
(Hue, Value, Chroma), Spectral reflectance (400-700 nm) ]  
Applicable instrument  
Spectrophotometer CM-700d/CM-600d/CM-2600d/CM-2500d  
4. Precautions for measurement  
1. If there is any opening between the target and measuring head, light leaks in from the opening, resulting in  
a lower Melanin value.  
To prevent measurement errors, ensure complete contact of the measuring head as much as possible.  
2. Be careful because pressing the measuring head too hard against the skin may cause congestion in the skin.  
3. Naevi (moles) in the dermis (blue naevus, naevus of Ota, etc.) cannot be measured.  
4. Do not perform measurement with the specimen measuring port directed towards your eyes and closed  
eyelids.  
4
 

Insignia Portable DVD Player NS CAPDVD7 User Manual
John Deere Automobile Parts OMPFP10808 User Manual
JVC Camcorder LYT2077 001B M User Manual
JVC DVD VCR Combo 1204MNH SW VE User Manual
JVC Stereo Amplifier KS AX4302 User Manual
JVC Stereo System XV THS3 User Manual
Kenwood Car Speaker KFC W1010 User Manual
KitchenAid Trash Compactor KUCS03FTSS User Manual
Kompernass Sewing Machine KH4000 User Manual
Kramer Electronics Video Gaming Accessories 2900 000503 User Manual