1. Introduction  
The 4-bay StorBladeTM 1U SCSI JBOD enclosure is designed for use with a  
host system to provide a high-end storage solution. The following is a summary  
of the 4-bay 1U enclosure features:  
The 4-bay StorBladeTM 1U SCSI JBOD Rackmount enclosure is a four  
drive enclosure that supports up to four 3.5" LP (Low-Profile) SCA (80-  
pin) drives. It supports single-ended, Ultra2 SCSI, and Ultra 160 SCSI.  
The SCSI enclosure has two SE/LVD (single-ended/Low Voltage  
Differential) Channels.  
2/4/6/8/10/12/15-bay Product Family Features  
TM  
FORTRA and StorBlade are families of high-end enclosures designed for  
high-volume performance storage solutions. The following table shows the  
features of the FORTRA 2/4/6/8/10/12/15-bay and the StorBladeTM  
products:  
4-bay1,3 6-bay*1,3 8-bay1 10-bay*1,2  
15-bay*1,3  
2-bay  
12-bay  
StorBlade  
Number of Device Bays  
2
1
4
1
6
1 or 2  
1 or 2  
2
8
10  
2
12  
2
15  
2
4
Number of Blowers  
2
2
Number of Power Supplies  
Number of I/O Channels (SCSI Only)  
SCSI SE/LVD Supported  
Fibre Channel Supported  
Hot-Swap Canisters  
1
1
2
2
2
2
1 or 2  
1
1
2
2
2
2
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
Removable Power Supplies  
Removable Blowers  
Fibre only  
Fibre Only  
Fibre only  
P
P
P
N+1 Power Supplies  
P
N+1 Blowers  
P
MIA Support (FC Only)  
P
P
P
P
Loop Expansion Support (FC Only)  
Daisy Chainable (SCSI Only)  
Built-in Termination (SCSI Only)  
Auto Termination (SCSI Only)  
SAF-TE/SES Ready (Optional)  
SAF-TE/SES Compatible  
SCSI to SCSI RAID Support  
Fibre to SCSI RAID Support  
Fibre to Fibre RAID Support  
Fibre to ATA RAID Support  
SCSI to ATA RAID Support  
(D)esktop/(T)ower/(R)ackmount  
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
Fibre only  
Fibre only  
P
P
P
P
P
P
R
D
D
DTR  
T
TR  
TR  
R
* 6/10/15-bay unit features apply to both Tower and Rackmount models  
1 Features are based on a standard configuration with no internal host controller(s) installed  
2 Fibre channel 10/15-bay enclosures have built-in SES  
3 Fibre Channel 2Gb Model available. 2Gb models use SFP transceivers.  
StorBladeTM SCSI JBOD Installation Guide Rev A  
1-1  
 
 
StorBladeTM  
StorBladeTM products use advanced mid-plane technology developed by JMR,  
that allows power supplies, drives, and all other enclosure components to  
interface into a single board. This provides superior performance and easy  
connectivity.  
The host interface supports single-ended, Wide Ultra2 SCSI (LVD), and Ultra  
160. Connections to a SCSI host can be made using a 68-pin (HD68) SCSI cable.  
4-bay Rackmount Specifications  
Dimensions/Weight  
Unit Weight  
Height  
Width  
35 lbs. (15.9kg)  
1-3/4" (1U) (44.45mm)  
19" (483mm)  
Depth  
22" (558.8mm)  
Power Supply  
Quantity:  
Power:  
1
200 Watts  
Input:  
Output:  
100-240 VAC; 50-60Hz  
+3.3V @ 14A  
+5V @ 20A  
+12V @ 6A  
Blower  
Quantity:  
Size:  
Air Flow:  
Noise:  
2
70mm (2.75”) each  
11.3CFM (0.32m3/min) each  
38dB(A)  
SCSI Features  
Daisy Chaining  
StorBladeTM SCSI enclosures include a SCSI I/O OUT port to allow additional  
devices and enclosures to be daisy-chained easily onto the bus. The limit of  
devices and enclosures that can be added is only regulated by the maximum cable  
length and maximum number of devices as specified by the SCSI standard. For  
specific connection and installation information, refer to Chapter 4.  
ID Selection  
0-15 device ID addresses are addressable in SCSI wide configurations and can be  
easily set-up via ID Jumpers for each slot located on the I/O module. For specific  
connection and installation information, refer to Chapter 4.  
StorBladeTM SCSI JBOD Installation Guide Rev A  
1-2  
 
 
2. Hardware Specification  
This chapter covers specification information for the 4-bay StorBladeTM  
enclosures. The following matrix describes the identification codes for the available  
TM  
configurations for all FORTRA and the StorBlade enclosures.  
FR XX X L 2 1 X 2 X XX X X  
SINGLE/DUAL CONTROLLER  
S = Single Controller  
D = Dual Controller  
BACKPLANE TYPE  
- = 1 Gigabit Backplane  
2 = 2 Gigabit Backplane  
CONTROLLER MANUFACTURER/MODEL#/INTERFACE  
-
=
None (Blank if at the end of P/N)  
H1 = Chaparral G5312/LVD Host/LVD Drives  
H2 = Chaparral G7313/Fibre Host/LVD Drives  
H3 = Chaparral K5312/LVD Host/LVD Drives  
H4 = Chaparral K7313/Fibre Host/LVD Drives  
H5 = Chaparral JSS122/LVD Host/LVD Drives  
H6 = Chaparral JFS124/Fibre Host/LVD Drives  
H8 = Chaparral JFS224/Fibre Host/LVD Drives  
FZ = Microtest FileZerver Network Attached/Ethernet/LVD Drives  
I2  
=
Infortrend Sentinel 2500-50/LVD Host/LVD Drives  
Infortrend Sentinel 2500-50 w/IFT9282F/Fibre Host/LVD Drives  
Infortrend EonRAID 2500-50 w/IFT9288B6B/Fibre Host/LVD Drives  
Infortrend EonRAID 5251F/2G Fibre Host/2G Fibre Drives  
Infortrend SentinelRAID 150/LVD Host/LVD Drives  
Infortrend EonRAID 7250-12U3D SCSI Host/ATA Drives  
Infortrend EonRAID 7250-12F2D Fibre Host/ATA Drives  
I3  
I4  
I5  
IS  
IF  
=
=
=
=
=
M3 = Mylex DAC-FFx/1G Fibre Host/1G Fibre Drives  
M5 = Mylex DAC-FFx2/2G Fibre Host/2G Fibre Drives  
SAF-TE/SES  
-
=
None (Blank if at the end of P/N)  
S = SAF-TE/SES  
POWER SUPPLY QUANTITY  
# = A number Equal to Power Supplies in Enclosure  
AC or DC POWER SUPPLY  
-
D
=
=
AC Power Supply  
DC Power Supply  
COLOR - CANISTER/ACCENT  
1 = Silver/Opal  
2 = Black/Black  
3 = Silver/Black  
4 = Blue/Blue  
DRIVE I/O SCSI CHANNELS or FIBRE LOOPS  
# = A Number Equal to Drive I/O Channels  
ENCLOSURE I/O  
L = SCSI 3 Ultra 160 (LVD/SE Multimode, Fast-Wide, HD68)  
F = 1 or 2Gb/s Fibre Channel  
A = ATA  
FIBRE GBIC READY  
- = No GBIC Slots  
G = GBIC Ready  
u.s. Power cords Included  
For International Models  
NUMBER OF DRIVES  
# = Drives (02,04,06,08,10,12,15)  
Add Power Cord:  
Australia = CBL-00602  
Europe = CBL- 00525  
FAMILY SERIES  
FR = Fortra Rackmount  
FT = Fortra Tower  
UK  
= CBL-00677  
1U = StorBlade Rackmount  
StorBladeTM SCSI JBOD Installation Guide Rev A  
 
2-1  
 
StorBladeTM  
Environmental Specifications  
Operating Temperature: 5°C to 40°C (41°F to 104°F)  
Storage Temperature: 0°C to 65°C (32°F to 149°F)  
Maximum ambient temperature is dependent on the recommended temperature to  
meet the MTBF rating as specified by the manufacturer of the installed devices.  
Electrical Specifications  
AC Inlet Type: IEC320/EN60320  
Power Cord: NEMA5-15P  
Power Supply: Auto-switching for 110/220V operation  
Agency Compliance  
StorBladeTM enclosures have been designed and built to comply with the FCC  
Class A, UL, CSA/TUV, CE, and C-Tick standards. For more information on  
FCC Class A compliance, see page 2.  
Packaging Specifications  
StorBladeTM packaging has been designed to be reusable and recyclable.  
Drives may be installed and shipped in the canisters as long as the canisters are in  
their original packaging location and are not installed in the enclosure. Shipping  
the unit with canisters and/or power supplies installed in the enclosure may cause  
damage to the enclosure or to the drives and will void the warranty.  
SAFETY TIP: Reshipping the enclosure with canisters, drives, or power  
supplies installed in the enclosure may cause damage to these  
components and will void the warranty  
SICHERHEITSHINWEIS: Der Versand des Gehäuses mit eingebauten  
Einschüben, Platten und Netzteilen kann zur Beschädigung dieser  
Komponenten führen und somit den Garantieanspruch gefährden.  
Packaging complies with ISTA (International Safe Transit Association) standards  
and has been ISTA certified.  
Each canister is pre-packaged in an anti-static bag. Do not throw the packaging  
away if the product is intended for re-shipping. When transporting or shipping a  
JMR approved shipping container must be used.  
Disclaimer  
The original product packaging has been tested and is safe under normal shipping  
circumstances. Reshipping the product without using the original product  
packaging will void the warranty. Do not ship the unit with canisters and/or  
power supplies installed in the enclosure as this will void the warranty and could  
cause damage to the unit and drives. The canisters should be packaged separately  
within the product packaging, as provided.  
StorBladeTM SCSI JBOD Installation Guide Rev A  
2-2  
 
 
StorBladeTM  
Thermal Specifications  
StorBladeTM enclosures have been designed to meet the air-flow/cooling  
requirements for popular 7,200, 10,000 and 15,000 RPM disk drives. Using a  
high performance blower, air is pulled in from all open vents and exhausted out  
the back of the unit.  
Rotation Vibration Specifications  
StorBladeTM enclosures have been designed to meet the rotation  
vibration/shock requirements for popular 7,200, 10,000 and 15,000 RPM disk  
drives.  
Fault Indication Features  
This section reviews the indicators that will notify the user of a power supply or  
blower that is in a fault state. More information is available in Chapter 5 power  
supply and blowers.  
Fault Indicators  
All slots will blink 'Red' in color on a blower fault. On a power supply fault, the  
front power supply LED will blink on and off.  
Audible Alert  
On a blower or power supply fault, an audible alert will sound.  
StorBladeTM SCSI JBOD Installation Guide Rev A  
2-3  
 
 
3. Device Installation  
This chapter covers SCSI device installation for 4-bay 1U rackmount enclosures.  
SCA Connection and Hot-Swapping  
The unit uses SCA-2 type connectors which provide a safe means of  
connection/disconnection when hot-swapping devices. In order to utilize this  
feature, the host adapter or RAID controller and host operating software must  
support the feature. Any SCA drive is capable of plugging directly into the  
backplane of the unit and should not require any additional cabling or  
connections.  
Canister Removal/Insertion  
1. Pull the handle out to unlock the canister from the StorBladeTM unit.  
Notice that the locking tab slides down as the handle is pulled out.  
2. Pull the canister straight out to remove. Ensure that any installed devices  
are spun down before full removal to prevent damage to the drive.  
Follow the steps in reverse to reinstall.  
SAFETY TIP: After disengaging a device from the enclosure, allow 10 seconds  
before pulling the canister out of the unit. This allows the device to  
properly spin/shut down before transport.  
Drive Installation  
Front  
Handle  
Screws  
Screws  
1. After removing the canister, place it on a static free surface along with the  
device to be installed.  
StorBladeTM SCSI JBOD Installation Guide Rev A  
3-1  
 
 
StorBladeTM  
2. Place the device in the canister with the four screw holes aligned with the  
holes in the device. Mount the drive by using the screws included with the  
unit. (use all 4 screws to mount the drive).  
3. Replace the canister into the unit.  
4. Repeat steps 1 through 3 until all devices are installed.  
5. Configure ID, and other options as required  
6. Establish host connection  
StorBladeTM SCSI JBOD Installation Guide Rev A  
3-2  
 
4. SCSI Setup  
This chapter covers SCSI device setup and option settings. Please take note of the  
installation warnings below before beginning setup.  
WARNING: Take care when connecting the unit to an AC power source to  
ensure that it is plugged-in to a circuit of the appropriate rating (110v or  
220v). For safe operation, the circuit should have over-current protection  
to prevent damage to the unit in the event of circuit overloading.  
WARNUNG: Vergewissern Sie sich, daß die Netzspannung (220V / 110V)  
korrekt eingestellt ist, bevor Sie das Gerät mit dem Stromnetz verbinden.  
Zur Sicherheit sollte das Netz über einen Überspannungsschutz zur  
Vermeidung von Schäden im Falle einer Überlast verfügen.  
WARNING: When connecting the unit to an AC outlet or power strip, ensure  
that the outlet has the proper connection for grounding. The AC power  
cables included with the unit have three prongs, one of which is used for  
the ground connection. Do not use a two prong AC cable with the unit  
since this will not allow for proper unit grounding and could cause  
problems with normal unit operation.  
WARNUNG: Bei der Verbindung der Unit mit einer Steckdose oder einer  
Verteilerdose sollten sie auf eine korrekte Erdung derselben achten. Die  
mitgelieferten Kaltgeräteanschlußkabel habe 3 Kontakte, von denen  
einer zur Erdung verwendet wird. Verwenden Sie kein Stromkabel mit 2  
Anschlüssen, da dieses keine korrekte Erdung ermöglicht und Probleme  
während des regulären Betriebs verursachen kann.  
Basic Personality Card Setup  
This section covers 4-bay 1U SCSI JBOD units using the basic personality card.  
This card does not have a controller interface built-in. The following Figure shows  
the slot numbering sequence used to refer to device bays and additionally shows the  
factory ID value for each slot. Slots 0-1 are on Channel A and Slots 2-3 are on  
Channel B.  
Slot 3, ID 3  
Slot 1, ID 1  
Slot 0, ID 0  
Slot 2, ID 2  
A
B
StorBladeTM SCSI JBOD Installation Guide Rev A  
 
4-1